Your colony
An Electrolyzer uses 1 kg/s water and outputs 888 g/s oxygen and 112 g/s hydrogen. A Duplicant uses 100 g/s oxygen and emits 2 g/s carbon dioxide.
The colony needs 800 g/s oxygen. 1 electrolyzer produces 888 g/s, so 88 g/s is spare.
Build list
What to do next
- 1
Build 1 Electrolyzer with 2 oxygen pumps near the top of the oxygen chamber and 1 hydrogen pump at the ceiling.
- 2
Pipe 600 kg water per cycle into the electrolyzer.
- 3
Connect the hydrogen line to 1 Hydrogen Generator.
- 4
Seal the room and put the oxygen vents low, away from the hydrogen pump.
- 5
Add an atmo sensor or a pressure vent so the electrolyzer does not over-pressurize the room.
Watch out for
- The hydrogen generator covers 800 W of the 840 W load. Add 1 coal generator or accept a small grid deficit.
- Oxygen leaves the electrolyzer at 70 °C. Without cooling, the colony oxygen will slowly heat the rooms it reaches.
The ratio behind the build
Eight Duplicants breathe 800 g/s. One Electrolyzer produces 888 g/s, which is why the standard answer is one electrolyzer for eight Duplicants, not one per Duplicant. The leftover 88 g/s is the buffer that keeps the room from dipping when a Duplicant walks past a vent.
The pumps are sized separately. Two oxygen pumps move 1,000 g/s, enough for the 888 g/s output. One hydrogen pump clears 112 g/s. That is three pumps, 720 W, plus the electrolyzer’s 120 W. The hydrogen generator returns 800 W, so the loop is 40 W short before lights or a filter.
Why water is the real limit
One electrolyzer drinks 600 kg of water per cycle while it runs. The colony only needs 480 kg per cycle of oxygen for eight Duplicants, so the machine cycles on and off. If the water pipe is empty, the oxygen stops immediately; there is no storage inside the electrolyzer beyond 1.8 kg of gas.
Why the oxygen comes out hot
The gas leaves at 70 °C. In a sealed room that heat has nowhere to go, and the electrolyzer’s own overheat temperature is 75 °C. A SPOM without cooling is a slow heater. Plan the cooling loop, or at least put the oxygen vents where the heat can spread into the base rather than into the machine room.
Common questions about this tool
How many Electrolyzers do I need for 8 Duplicants?
One. Eight Duplicants breathe 800 g/s and one Electrolyzer produces 888 g/s. The planner adds a second only when you ask for a buffer above 11%.
How many gas pumps does a SPOM need?
Three for a standard build: two for oxygen and one for hydrogen. Two oxygen pumps move 1,000 g/s, which covers the 888 g/s output; the hydrogen pump clears 112 g/s.
Can a SPOM power itself?
Almost. One Electrolyzer and three pumps draw 840 W; the Hydrogen Generator makes 800 W. That is a 40 W deficit before lights, filters or a second pump. A gas filter adds another 120 W.
How much water does an Electrolyzer use?
1 kg/s, or 600 kg per cycle, while it runs. Eight Duplicants only need 480 kg per cycle of oxygen, so the electrolyzer cycles on and off.
Why is hydrogen in my oxygen line?
Hydrogen collects at the ceiling. If the hydrogen pump is low or missing, it enters the oxygen pump. Put the hydrogen pump in the top row, the oxygen pumps lower, and use a gas filter only as a backup.