The geyser and the colony
Cool Steam Vent emits Steam at 110 °C. Its raw rate is 1,000–2,000 kg per cycle during the active year.
At the typical roll it averages 1.50 kg/s (900 kg/cycle), with 75 active and 50 dormant cycles. You need 600 kg/cycle.
Active year vs dormancy
Output range
Watch out for
- The geyser emits at 110 °C. The water or gas needs cooling before it reaches crops or Duplicants.
- Gas geysers pressurize a room quickly. Use a gas pump and a high-pressure vent, not an open room.
Why the eruption number is not the average
A Cool Steam Vent listed at 1,000–2,000 kg per cycle does not deliver 1,500 kg every cycle. It erupts for part of a cycle, stays active for part of a year, and then goes dormant. The average is the rate multiplied by the active share of the year.
At a typical roll, 1,500 kg per cycle × 60% active ÷ 600 seconds is about 1.5 kg/s, or 900 kg per cycle. That is the number the colony can plan around.
What the storage number means
During the dormant period the geyser produces nothing. If the colony keeps using 900 kg per cycle and the geyser sleeps for 50 cycles, the buffer has to hold 45,000 kg. A liquid reservoir holds 5,000 kg, so that is nine reservoirs, not one.
Taming, not just tapping
A Cool Steam Vent at 110 °C needs a sealed room and a Steam Turbine before its water is useful. A Cool Slush Geyser at -10 °C is a heat sink, not a water source you can send straight to the farm. The element and temperature at the top of the tool decide what the geyser can actually do.
Common questions about this tool
How much does a Cool Steam Vent produce?
A typical roll averages about 1.5 kg/s, or 900 kg per cycle. The range is roughly 0.67 to 2.67 kg/s depending on the rate and active-period rolls. It emits at 110 °C.
Why does my geyser stop producing?
Every geyser has an eruption cycle and a dormancy cycle. It stops between eruptions and again for the dormant part of its year. The planner shows both durations.
How much storage does a geyser need?
Enough to cover the dormant period. If the colony uses 900 kg per cycle and the geyser sleeps for 50 cycles, the buffer is about 45,000 kg, or nine liquid reservoirs.
Can a Cool Steam Vent cool my base?
No. It emits at 110 °C; it is a heat source, not a heat sink. A Cool Slush Geyser at -10 °C is the one that can absorb heat.
Do geyser numbers change with the seed?
Yes. Each geyser rolls its rate, eruption length, active percentage and year length. Two Cool Steam Vents on the same map can differ, which is why the planner lets you choose low, typical or high rolls.