GameToolForgeOxygen Not Included
Planner · U59 build

Cooling Planner: Aquatuners, Turbines and Heat

A cooling loop is a heat budget. The aquatuner moves heat out of the liquid; the turbine deletes it from the steam. This planner checks both sides and tells you which one is too small.

No save uploadFree, in the browser
A multi-level Oxygen Not Included base with pipes and machines
Inputs

What are you cooling?

Cooling job

Lights, kitchen and a few machines; not a measured load.

Coolant
1 Aquatuner and 1 Steam Turbine handle 25 kDTU/s.

One aquatuner moves 585 kDTU/s with Polluted Water. At 200 °C steam, one turbine can delete up to 790 kDTU/s and produce up to 850 W. The aquatuner power draw is not added again as heat; the steam load is the heat removed from the coolant.

Aquatuners1585 kDTU/s each
Steam turbines1790 kDTU/s each
Power-1,173 W1,200 W draw / 27 W gen
Turbine self-heat3 kDTU/sMust be cooled separately

Build list

Thermo Aquatuner×1
Steam Turbine×1

Check before you build

  • The turbine building must stay below 100 °C. Its own 10% waste heat goes into the building, so it still needs a cooling loop.
  • Polluted Water freezes at -20.6 °C and boils at 119.4 °C. Keep the loop inside that range.
  • One aquatuner is the smallest unit. At 25 kDTU/s it will cycle on and off rather than run continuously.
STEAM ROOM 200 °CAquatuner−14 °C per passCoolantin/outSteam Turbine850 W at 200 °C10% waste heat stays in the buildingcool coolant returns to the baseTurbine body must staybelow 100 °C
The aquatuner moves heat out of the coolant. The turbine deletes it from the steam, but keeps 10% in its own building.

Two heat moves, not one

The aquatuner removes heat from the coolant: 10 kg/s × specific heat × 14 °C. With polluted water that is about 585 kDTU/s. That heat enters the steam room. The aquatuner's 1.2 kW is power draw, not a second heat load. The turbine then deletes 90% of the heat in the steam and keeps 10% in its own building.

At 200 °C one turbine deletes about 790 kDTU/s and produces 850 W. One polluted-water aquatuner adds about 586 kDTU/s, so one turbine covers it with room to spare. At 150 °C the same turbine deletes about 414 kDTU/s, so the same loop needs two.

Why the turbine still needs cooling

A turbine stops when its body reaches 100 °C. Its own 10% waste heat is small compared with the steam room, but it is enough to cook the building if nothing removes it. The turbine cooling loop is not optional, and it is separate from the steam loop.

What to check if it does not cool

If the coolant comes back warm, check the turbine first: steam temperature, steam mass, water output and turbine body temperature. If the turbine is running but the room still climbs, the heat load is larger than the loop, or the aquatuner is not running because the coolant froze or the pipe is blocked.

The coolant range is a hard limit
Polluted water freezes at -20.65 °C and boils at 119.35 °C. If the loop target is outside that range, the aquatuner will break the pipe. The tool prints the range for the coolant you choose.
Questions

Common questions about this tool

How much heat does one Aquatuner remove?

10 kg/s of coolant cooled by 14 °C. Polluted water removes about 585 kDTU/s; super coolant removes about 1,181 kDTU/s. The 1.2 kW is its power draw, not a second heat load.

How many Steam Turbines per Aquatuner?

At 200 °C steam, one turbine deletes about 790 kDTU/s and comfortably covers one polluted-water aquatuner. At 150 °C it deletes about 414 kDTU/s, so you need two.

Why is my Steam Turbine not running?

Steam below 125 °C will not start it, and a turbine body above 100 °C shuts it down. Check the steam temperature and the turbine cooling loop before adding more turbines.

What is the best coolant?

Polluted water is the practical early coolant: specific heat capacity 4.179, freezes at -20.65 °C and boils at 119.35 °C. Super coolant is better but needs fullerene. Brine and salt water are useful for cold loops but move less heat.

Does the aquatuner power count as heat?

No. The 1.2 kW is the electrical draw. The heat the loop has to delete is the heat removed from the coolant; the planner sizes the turbines from that heat load.