GameToolForgeOxygen Not Included
Guide · U59 build

Geyser Guide: Read the Average, Not the Eruption

The number on the geyser tooltip is not what the colony gets. Average output depends on the eruption length, the active percentage and the year length.

No save uploadFree, in the browser
A rocket and a vent on the surface
01

Average output, not eruption output

A geyser has two cycles: an eruption cycle and a dormancy cycle. During the active year it erupts and rests; during dormancy it does nothing. The average output is the rate multiplied by the active share of the year, divided by 600 seconds.

A typical Cool Steam Vent at 1,500 kg per cycle and 60% active averages 1.5 kg/s, or 900 kg per cycle. The game rolls the rate, the eruption length, the active percentage and the year length independently, so two vents of the same type can differ.

Active 75Dormant 50
eruption cycles inside the active yearbuffer drains
Check a geyserPick the type and the roll to see the average and the buffer.
02

The buffer is the real cost

A geyser fills a buffer while it is active and drains it while it sleeps. If the colony uses 900 kg per cycle and the geyser sleeps for 50 cycles, the buffer is 45,000 kg. A liquid reservoir holds 5,000 kg, so that is nine reservoirs.

This is why “it says 1.5 kg/s” is not enough. The colony needs the average to cover demand and the storage to cover dormancy. A geyser that is just above demand has no margin for a second consumer or a bad roll.

03

Taming the three common types

A Cool Steam Vent emits at 110 °C. Seal it, pump the steam into a Steam Turbine and collect the 95 °C water. A Cool Slush Geyser emits at -10 °C and is a heat sink; use it to cool the base before the water warms up. A Natural Gas Geyser emits at 150 °C and feeds a Natural Gas Generator; a typical roll supports one generator at 90 g/s.

Molten volcanoes are a different job. They need a controlled room, a way to solidify the metal and a cooling loop that can survive the burst. Do not treat a volcano like a water geyser.

Average output is the number that matters

A geyser’s average is the output rate multiplied by the active percentage, then adjusted for the dormancy. A Cool Steam Vent that produces 1.5 kg/s while active and is active 60% of the time averages about 0.9 kg/s. The eruption rate is not the number the colony drinks.

Storage turns the average into a usable supply. A full cycle of dormancy needs a buffer sized from the average demand, not from the eruption burst. The Geyser Planner shows the reservoir count and the demand coverage for the selected roll.

  • Average = rate × active %
  • Dormancy is part of the year
  • Buffer for dormancy
  • Eruption rate is not average
Questions

Common questions

What is a good Cool Steam Vent?

One that averages at least 1.5 kg/s. That is 900 kg per cycle, enough water for about 13 Duplicants through an electrolyzer before crops.

How do I tame a Cool Steam Vent?

Seal it in an insulated room, pump the steam into a Steam Turbine, and collect the 95 °C water. The turbine turns the heat into power and the water into a usable supply.

How long do geysers stay dormant?

It varies by roll. A typical geyser is active for 60% of a 125-cycle year, so it sleeps for about 50 cycles. Use the planner’s storage number.

Can a Natural Gas Geyser power the base?

A typical one averages about 0.105 kg/s, which supports one Natural Gas Generator at 90 g/s. A high roll can feed a second generator, but do not plan the base around it.