GameToolForgeOxygen Not Included
Guide · U59 build

Base Layout Guide: Build for the Pipes First

The rooms are the easy part. The layout that survives is the one that left space for pipes, wires, ventilation, cooling and a transit tube.

No save uploadFree, in the browser
A finished recreation room
01

The corridor and the spine

A five-tile corridor fits a ladder, a fire pole, a liquid lock and a transit tube. Three tiles works until the first pipe has to cross the shaft. A six-tile utility spine on one side keeps water, polluted water, gas, power and ventilation out of the rooms.

This is the part that is expensive to change later. Rooms can be rebuilt in a few cycles; a ladder shaft in the middle of the bedrooms cannot be moved without cutting the base in half.

UTILITY SPINEBarracks6 × 4Bath6 × 4Great Hall8 × 4Kitchen8 × 4Farm8 × 4Lab8 × 4Power Plant8 × 4

Schematic, not a tile-perfect plan. The dark strip is the reserved utility spine.

Lay out your roomsChoose the rooms and see the footprint.
02

Room sizes that work

A barracks needs 12 tiles; the planner uses 24. A great hall needs 32; the planner uses 32. A laboratory needs 32; a farm needs 12; a creature stable needs 96 for eight critters. The planner uses a comfortable rectangle, not the bare minimum, because a room at the minimum has no space for decor or a second building.

Keep the bathroom next to the barracks, the kitchen next to the great hall, and the industrial block at the edge. The point is not symmetry; it is that the Duplicants do not walk through the kitchen to reach the toilet.

03

Where the heat and the CO2 go

A refinery, a generator and a crusher make heat and carbon dioxide. Put them behind an insulated wall and a liquid lock, with their own cooling loop. If the industrial block shares a corridor with the bedrooms, the heat and the exhaust share it too.

The base does not need to be one sealed box. A living wing, a farm wing and an industrial wing can each have their own atmosphere and temperature. The corridor is the only place they meet.

The corridor is a utility decision

A 5-tile main corridor leaves room for a ladder, a fire pole, a transit tube and two walking lanes. A 6-tile utility spine gives the pipes and wires a dedicated vertical route, so a later room does not force the colony to rebuild the middle of the base.

The room sizes are not cosmetic: a Barracks is 6×4 in this plan (24 tiles), a Great Hall 8×4 (32 tiles), a Laboratory 8×4 (32 tiles), and a Farm 8×4 (32 tiles). Leave the rooms at their planned size and let the corridor absorb the leftover space.

  • 5-tile corridor
  • 6-tile utility spine
  • Room blocks on a grid
  • Pipes before decor
Questions

Common questions

What is the best base layout?

There is no single best, but a five-tile central corridor with rooms on both sides and a dedicated utility spine handles most colonies. Keep industry at the edge and bedrooms away from it.

How much space does an eight-Duplicant base need?

The core rooms in the planner fit in roughly 40 × 25 tiles including a five-tile corridor and a six-tile utility spine. That is the layout footprint, not the dug-out area.

Where should the bathroom go?

Next to the barracks, on the same corridor, with the sink on the way out. Keep it away from the kitchen and the food storage.

Why do players rebuild their bases?

Usually because the ladder shaft, pipes or wires were placed inside rooms and cannot be expanded. A utility spine and a wider corridor prevent that.