GameToolForgeOxygen Not Included
Planner · U59 build

Base Layout Planner for a Colony That Will Not Be Rebuilt

Most bases are rebuilt because the pipes had nowhere to go, not because the rooms were wrong. This planner reserves the corridor and the utility spine before you place the first tile.

No save uploadFree, in the browser
A finished recreation room in an Oxygen Not Included base
Inputs

Rooms you want

Drag to change the packing order
Barracks
Plumbed Bathroom
Great Hall
Kitchen
Farm
Laboratory
Power Plant
More rooms Optional
7 rooms fit in 30 × 22 tiles.

The plan uses a 5-tile corridor and a 6-tile utility spine. Room tiles are 208; circulation and spare space add about 320 more.

Footprint30 × 22tiles, including corridors
Room tiles2087 rooms
Build mass66 tat 100 kg per tile block
Corridor5 tilesutility spine reserved

Zone plan

Living wingBarracks · Plumbed Bathroom · Great Hall · KitchenBeds, bathroom, food and morale next to the main corridor.
Farm wingFarmCrops, ranches and parks away from industrial heat.
Research wingLaboratoryResearch and hospital rooms, away from industrial heat.
Industrial wingPower PlantMachines at the edge, behind an insulated wall and a liquid lock.

Schematic layout

UTILITY SPINEBarracks6 × 4Bath6 × 4Great Hall8 × 4Kitchen8 × 4Farm8 × 4Lab8 × 4Power Plant8 × 4

Schematic, not a tile-perfect plan. The dark strip is the reserved utility spine.

Checks

✓
Beds8
✓
Toilets2 recommended
✓
FoodRoom selected
✓
FarmRoom selected
✓
PowerRoom selected

Build order

  1. 1

    Build the corridor and ladder shaft first; rooms attach to it later.

  2. 2

    Reserve one vertical shaft for pipes, one for wires, and one for the transit tube. The 6-tile spine is for that.

  3. 3

    Put the industrial block at the edge of the base, behind an insulated wall, with its own cooling loop.

  4. 4

    Keep the kitchen next to the great hall and away from the toilets.

Why the corridor comes first

Rooms can be rebuilt; a ladder shaft cannot be moved without cutting the base in half. A five-tile corridor fits a ladder, a fire pole, a liquid lock and a transit tube with room for Duplicants to pass. Three tiles seems efficient until the first pipe has to cross it.

The utility spine

Every base eventually needs four vertical routes: clean water, polluted water, gas and power. Add ventilation and the transit tube and the number grows. A six-tile spine on one side of the base keeps those routes out of the rooms and makes maintenance possible.

What the schematic is not

This is a space plan, not a tile-perfect blueprint. It shows the rooms, the corridor and the spine at the sizes the game requires. The exact wall positions depend on the terrain, the geysers and the ladder you already built.

The industrial block belongs at the edge
A refinery, a generator and a crusher make heat and carbon dioxide. Put them on the far side of the utility spine, behind an insulated wall and a liquid lock, so the base does not inherit their exhaust.
Questions

Common questions about this tool

How big should a room be?

A barracks needs 12 tiles, a great hall 32, a laboratory 32, a farm 12 and a creature stable 96 for eight critters. The planner uses a comfortable rectangle for each room, not the bare minimum.

How wide should the main corridor be?

Five tiles is a practical default. It fits a ladder, a fire pole, a liquid lock and a transit tube without blocking traffic. Three tiles works early but usually has to be widened.

Why reserve a utility spine?

Pipes, wires, ventilation and the transit tube all want vertical space. Reserving one 6-tile shaft keeps them out of the rooms and makes later changes possible without tearing down the base.

Where should the industrial block go?

At the edge of the base, behind an insulated wall, with its own cooling loop and a liquid lock. Heat and carbon dioxide should not travel through the bedrooms.

Do I need a great hall?

It is one of the cheapest morale rooms: a mess table, a decorative item and a recreation building in 32 tiles. The planner includes it in the core set.