GameToolForgeOxygen Not Included
Planner · U59 build

Colony Troubleshooter: What Is Actually Wrong?

The game shows the symptom, not the cause. Pick what you can see and the troubleshooter gives you the checks in the order that finds the cause fastest.

No save uploadFree, in the browser
A colony with an oxygen overlay showing problem areas
Step 1

What do you see?

Gas

Gas pipe is blocked

The pump has gas but the pipe will not move it.

VENTover pressure×pump pushes

Check these in order

1

The vent is over pressure

Check: Click the vent. A normal gas vent stops at 2 kg per cell; a high-pressure vent stops at 20 kg.

Fix: Move the vent to a larger room, add a second vent, or use a high-pressure vent.

2

The pipe is full and has no consumer

Check: Follow the pipe from the pump to the end. If it loops back into itself, the packet has nowhere to go.

Fix: Add a vent, storage or a bridge that leads to a real destination. Do not loop a full pipe into itself.

3

A bridge faces the wrong way

Check: The arrow on a bridge shows the direction. The input is the back, the output is the arrow.

Fix: Rebuild the bridge with the arrow pointing away from the pump.

4

The filter is set to the wrong gas

Check: Open the filter and read the selected element. A filter set to oxygen will send hydrogen back to the output.

Fix: Set the filter to the gas you want to keep, or remove it and fix the pump placement.

5

The pipe is the wrong type

Check: A gas pipe cannot carry liquid and a liquid pipe cannot carry gas.

Fix: Rebuild the line with the matching pipe and pump.

Start at the end, not the pump
A blocked pipe is a downstream problem. Walk the line from the destination back to the pump; the first full or disconnected segment is the cause.

Related tools

Why the symptom is not the cause

Oxygen Not Included reports the last thing that failed, not the first. “Pipe blocked” appears at the pump even when the real problem is a full reservoir six rooms away. The checks are ordered from the destination back to the source so the first failure is the one you fix.

One change at a time

If you change the pump, the filter and the vent at once, you will not know which one fixed it. Change one segment, let the game run for a few seconds, then re-read the pipe.

What this page cannot see

The troubleshooter cannot read your save. It gives the ordered checks for the symptom you pick; the actual reading comes from clicking the building, the pipe or the overlay in your colony.

Questions

Common questions about this tool

Why does my pipe say blocked?

The output has nowhere to go: the vent is over pressure, the reservoir is full, the pipe is looping into itself, or a bridge points the wrong way. Start at the output, not the pump.

Why is my Steam Turbine overheating?

Its body is above 100 °C. The turbine dumps 10% of the heat it removes into its own building, so it needs a cooling loop even when the steam is perfect.

Why did my Electrolyzer stop?

No water, no power, output gas backed up above 1.8 kg, or the room is too hot. Check the input pipe, the power line and the gas outlet in that order.

Why is gas not moving?

A gas pump moves 500 g/s and stops when the pipe is full or the vent is over pressure. A filter with the wrong element, a blocked bridge or a loop with no consumer will also stop the flow.

Why is my bathroom not working?

The loop needs a sieve, a reservoir and a bridge. Without the bridge the water has no direction when the toilet is idle; without the reservoir the sieve starves.