GameToolForgeOxygen Not Included
Guide · U59 build

Why Is My Steam Turbine Overheating?

The turbine deletes heat from steam, but it keeps 10% of that heat in its own building. If that heat has no route out, the turbine cooks itself and stops.

No save uploadFree, in the browser
A steam turbine room in a base
01

Why the turbine heats itself

A Steam Turbine deletes 90% of the heat in the steam and puts 10% into its own building. At 200 °C that is about 79 kDTU/s going into the turbine. If the building has no cooling loop, its temperature climbs until it reaches 100 °C and stops.

The turbine also sits next to a 125–200 °C steam room. Even the small 10% is enough to cook it when the room is insulated and the turbine is sealed.

STEAM ROOM 200 °CAquatuner−14 °C per passCoolantin/outSteam Turbine850 W at 200 °C10% waste heat stays in the buildingcool coolant returns to the baseTurbine body must staybelow 100 °C
The aquatuner moves heat out of the coolant. The turbine deletes it from the steam, but keeps 10% in its own building.
02

The fix is a second loop

Run a coolant loop through the turbine building, usually the same coolant that feeds the aquatuner. Radiant pipes inside the turbine room, a reservoir and a bridge give the loop direction and buffer.

Do not rely on the steam room to cool the turbine. The steam room is the heat source. The turbine needs a route to the cold side of the loop.

Size the loopThe planner includes the turbine’s 10% waste heat.
03

The other stops

A turbine also stops when the steam is below 125 °C, when the steam mass is too low, when the water output is blocked, or when a smart battery at its threshold turns it off. Check those before adding a second turbine.

If the body temperature is fine and the steam is hot but the turbine still does not run, look at the output pipe and the automation. The status item names the specific stop.

The turbine is a cooled building

A Steam Turbine deletes heat from steam and keeps 10% of it in its own building. That is why an uncooled turbine reaches 100 °C and stops even when the steam room is perfect. The turbine cooling loop is part of the design, not an optional extra.

At 200 °C a turbine deletes about 790 kDTU/s and produces 850 W. At 150 °C it deletes about 414 kDTU/s and produces about 445 W. The body temperature is separate from the steam temperature; cooling the building does not cool the steam room.

  • 10% heat stays in building
  • Body limit 100 °C
  • 200 °C: 790 kDTU/s
  • 150 °C: 414 kDTU/s
Questions

Common questions

At what temperature does a Steam Turbine stop?

The turbine building must stay below 100 °C. Its overheat temperature is higher, but it stops producing when the body reaches 100 °C.

Why is my turbine hot?

It returns 10% of the heat it removes to its own building, and it sits next to a 125–200 °C steam room. Without a cooling loop on the turbine, the body climbs.

Can the turbine cool itself?

No. The 10% waste heat plus the room heat has to be removed by a liquid loop, usually the same coolant loop that feeds the aquatuner.

Why is the turbine not running at 125 °C?

It needs steam mass as well as temperature. A thin steam atmosphere may not supply 2 kg/s, and a blocked water output stops it just as fast.