GameToolForgeOxygen Not Included
Planner · U59 build

Steam Turbine Planner: How Many Turbines for the Heat?

A turbine is a heat sink with a temperature window. Below 125 °C it does nothing; at 200 °C it deletes the most heat and produces full power.

No save uploadFree, in the browser
A steam turbine room in a base
Inputs

Heat and steam

A turbine is a heat sink
It deletes 90% of the steam heat and keeps 10% in its own building. The building has to stay below 100 °C.
1 Steam Turbine deletes 585 kDTU/s at 200 °C.

Each turbine can delete up to 790 kDTU/s and produce up to 850 W. It needs 1.48 kg/s of steam and returns 1.48 kg/s of water at 95 °C.

Turbines1790 kDTU/s each
Power630 W850 W each at full load
Steam1.48 kg/s1.48 kg/s water out
Self-heat59 kDTU/scool the turbine building

Watch out for

  • The turbine building keeps 10% of the heat it deletes and must stay below 100 °C.
STEAM ROOM 200 °CAquatuner−14 °C per passCoolantin/outSteam Turbine850 W at 200 °C10% waste heat stays in the buildingcool coolant returns to the baseTurbine body must staybelow 100 °C
The aquatuner moves heat out of the coolant. The turbine deletes it from the steam, but keeps 10% in its own building.

Why 200 °C is the useful target

At 200 °C a turbine deletes about 790 kDTU/s and produces 850 W. That covers one polluted-water aquatuner. At 150 °C it deletes about 414 kDTU/s, so the same loop needs two turbines.

The water return

The turbine returns 2 kg/s of water at 95 °C per full unit. If the output pipe is full, the turbine stops even with perfect steam. Plan the return line before the steam room.

The 10%

The turbine keeps 10% of the heat it deletes. That is why a turbine in a sealed, uncooled box climbs to 100 °C and stops. The turbine cooling loop is part of the design, not an optional extra.

Why steam temperature changes the turbine count

A Steam Turbine deletes 0.9 × 2 kg/s × 4.179 × (steam °C − 95). At 200 °C that is about 790 kDTU/s; at 150 °C it is about 414 kDTU/s. The same heat load therefore needs one turbine at 200 °C and two at 150 °C.

Power scales with the same temperature window: 850 W at 200 °C, about 445 W at 150 °C. The turbine still needs 2 kg/s of steam and returns 2 kg/s of water at 95 °C per full unit. The steam room has to supply both the temperature and the mass.

  • 125 °C minimum
  • 200 °C: 790 kDTU/s
  • 150 °C: 414 kDTU/s
  • 2 kg/s steam
Questions

Common questions about this tool

How much heat does one Steam Turbine delete?

At 200 °C it deletes about 790 kDTU/s. At 150 °C it deletes about 414 kDTU/s. The turbine needs 2 kg/s of steam and returns water at 95 °C.

How much power does a Steam Turbine make?

Up to 850 W at 200 °C. At 150 °C the output is about 445 W. Power scales with the steam temperature, not with the heat load alone.

Why does the turbine stop at 100 °C?

The building must stay below 100 °C. It keeps 10% of the heat it removes, so it needs its own cooling loop.

How many turbines for one aquatuner?

At 200 °C one turbine covers a polluted-water aquatuner. At 150 °C the same loop needs two.