GameToolForgeOxygen Not Included
Guide · U59 build

Wire Capacity Guide: Which Wire for Which Load?

A wire is a rated ceiling. The generator can make more, but the wire melts above its rating; the transformer is how a heavy backbone feeds a small room circuit safely.

No save uploadFree, in the browser
Power wires and generators in a base
01

The four wire ratings

Normal wire carries 1 kW, conductive wire 2 kW, heavy-watt wire 20 kW and heavy conductive wire 50 kW. The rating is a hard ceiling; a consumer above it damages the circuit.

A room circuit usually uses normal or conductive wire. The generator backbone uses heavy-watt or heavy conductive wire because it has to carry every room at once.

Generator600 W–2 kWHeavy-watt20 kWTransformer4 kWRoom wire1–2 kW
The backbone carries the total; the transformer protects the room wire.
Size the power gridAdd the machines and see the demand, wire and battery.
02

The transformer is the adapter

A Power Transformer passes up to 4 kW from the heavy backbone into a small wire circuit. That lets a 20 kW backbone feed several 1–2 kW rooms without exposing the room wire to the full generator current.

Put the transformer before the room circuit, not after it. The wire between the backbone and the transformer is still heavy-watt wire.

03

Why a wire overloads

The consumers on one circuit draw more than its wire rating. A refinery and a glass forge together are 2,400 W, so a normal 1 kW wire cannot carry both.

Split the circuit, upgrade the wire, or move one machine to a second transformer. Adding a bigger generator does not fix a wire that is already too small.

  • Normal 1 kW.
  • Conductive 2 kW.
  • Heavy-watt 20 kW.
  • Heavy conductive 50 kW.
  • Transformer 4 kW.

The wire rating is not the generator rating

A 2 kW generator can feed a 2 kW conductive wire, but it cannot feed a 1 kW normal wire. The wire rating is the ceiling for the circuit, not for the generator. A transformer is the adapter: it passes up to 4 kW from the heavy backbone into a smaller room circuit and protects the smaller wire.

When a circuit trips, count the consumers on that wire before adding a generator. A refinery and a glass forge together are 2,400 W, so a normal 1 kW wire cannot carry both even if the generators can produce 5 kW. Split the circuit or upgrade the wire; a larger generator does not change the wire rating.

  • Normal wire: 1 kW
  • Conductive: 2 kW
  • Heavy-watt: 20 kW
  • Heavy conductive: 50 kW
  • Transformer: 4 kW
Questions

Common questions

How much power can normal wire carry?

1 kW. Conductive wire carries 2 kW. Heavy-watt wire carries 20 kW and heavy conductive wire 50 kW.

Why does my wire overload?

The consumers on that circuit draw more than the wire rating. Split the circuit or put a transformer between the backbone and the room.

What does a transformer do?

A Power Transformer passes up to 4 kW from the heavy backbone into a small wire circuit and limits the draw on that circuit.

Can I use conductive wire everywhere?

It is fine for a 2 kW room circuit. The heavy backbone still needs heavy-watt or heavy conductive wire for the generators.