GameToolForgeOxygen Not Included
Guide · U59 build

Thermo Aquatuner Not Cooling? Check Coolant, Power and Pipe

The aquatuner is rarely the broken part. The coolant, the pipe direction or the heat sink usually is.

No save uploadFree, in the browser
Pipes and an aquatuner in a base
01

Power and input

The aquatuner draws 1,200 W and needs 10 kg/s of liquid. A disconnected wire, a dead battery or a dry input pipe stops it before the cooling loop can do anything.

Check the input pipe first, then the power. If the pipe is full but the machine is idle, the problem is the output or the loop direction.

Power1,200 WLiquid in10 kg/s−14 °Cper passTurbinedelete the heat
The aquatuner only moves heat; the loop still has to delete it.
Check the cooling budgetEnter the heat load and coolant to size the loop.
02

The coolant range

Polluted water freezes at -20.65 °C and boils at 119.35 °C. If the loop target is outside that range, the pipe breaks and the coolant is lost. Super coolant is for colder loops; petroleum or oil is for hotter ones.

A coolant that is already frozen or boiled is not moving. Replace the liquid and check the target temperature before restarting.

03

The heat has to leave

The aquatuner moves heat from the coolant into the room around it. If the steam room cannot delete that heat, the room and the coolant both climb. The turbine is the other half of the loop.

If the aquatuner runs but the rooms stay warm, check the radiant pipe section, the loop direction and the turbine. The aquatuner may be moving heat into a room that cannot get rid of it.

What one aquatuner can and cannot do

One Thermo Aquatuner cools 10 kg/s of coolant by 14 °C. With polluted water that is about 585 kDTU/s; with super coolant it is about 1,181 kDTU/s. The machine draws 1,200 W and does not delete the heat — it moves it into the room around the building. The steam turbine is the other half of the loop.

If the aquatuner is powered and the pipe is full but the room still warms, follow the heat. The coolant returns to the loop, the aquatuner adds the heat to its room, and the turbine must remove it from the steam. A loop with no turbine is a heat pump with nowhere to dump the heat.

  • 10 kg/s per pass
  • −14 °C per pass
  • 1,200 W
  • Polluted water: 585 kDTU/s
Questions

Common questions

Why is my Aquatuner not cooling?

It may be unpowered, dry, or the coolant may be frozen or boiled. Check the input pipe and the coolant range first.

What coolant should I use?

Polluted water is the standard early coolant. It freezes at -20.65 °C and boils at 119.35 °C. Use super coolant for colder loops.

Why does the coolant get hotter?

The aquatuner removes 14 °C per pass, but if the steam room cannot delete the heat, the loop and the room both climb.

Why is the aquatuner pipe blocked?

The output has nowhere to go: a full pipe, a reversed bridge, or a closed loop with no consumer.